SPST Freeze Protection Control (120/250V)

SKU: SFPC

$23.95each

20 People watching this product now!

Fast Shipping

Carrier information

20k products

Payment methods

24/7 Support

Unlimited help desk

2-day Delivery

Track or off orders

Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “SPST Freeze Protection Control (120/250V)”

Your email address will not be published. Required fields are marked *

Description

Protects air conditioning evaporator coils from freezing.

Features

  • Brownout protection
  • UL 873 recognition as compressor controller
  • Helps prevent scroll compressor reversal
  • 3-10 minute adjustable time delay
  • Fast response time: 16ms
  • Prevents low voltage starts
  • Eliminates relay chatter due to thermostat bounce or tampering
  • Works with anticipator-type thermostats Patented: US Parent No. 4,991,049

Mode of Operation - Upon application power, the load is energized. When the thermostat or other switch opens or there is a loss of power, the load is de-energized and the delay period begins. The compressor will not start again during the delay period. Restart occurs after the delay period has elapsed.

Installation & Operation Notes:

  • Disconnect power at all sources and verify that all circuits are de-energized before starting work
  • Mount the contactor securely in the control compartment or electrical panel as directed by the equipment manufacturer
  • Move line, load, and control wires from the existing contactor to the new contactor, matching wiring diagrams and terminal markings
  • After energizing the system, verify that the contactor pulls in and opens cleanly, with proper operation during system start and stop cycles
  • Confirm that all terminations are tight and that wiring is supported to prevent strain at the terminals

Maintenance & Troubleshooting:

  • Inspect the contactor during routine HVAC maintenance for pitted or burned contacts, coil discoloration, or mechanical binding
  • Replace the contactor if the coil fails to energize, if the contacts do not close fully, or if there is evidence of overheating or excessive humming
  • If repeated contactor issues occur, verify that load current and control voltage are within specification and that short cycling is not overstressing the contactor

Certifications & Compliance:

  • Meets ARI 780/790 Standard

User Reviews & Q&A Summary:

  • Common theme is "correct part" for the intended replacement, with users reporting it worked as expected after installation
  • Review feedback frequently mentions straightforward installation for a direct replacement
  • Value and fulfillment are recurring positives (good deal/price and fast shipping)

Product Highlights

Product Highlight: Voltage120/250V

Specs

Product Type:

Miscellaneous

Application:

Air Quality

Voltage:

120/250V