Flame Sensor

Features

  • Length (Mounting Flange to Sensor Tip): 2-1/2"
  • Length - Sensor Offset : 1-9/16"
  • Angle - Sensor Offset (degrees): 90
  • Termination: 1/4" Male Quick Connect

Mode of Operation - Upon application power, the load is energized. When the thermostat or other switch opens or there is a loss of power, the load is de-energized and the delay period begins. The compressor will not start again during the delay period. Restart occurs after the delay period has elapsed.

Installation & Operation Notes:

  • Disconnect power at all sources and verify that all circuits are de-energized before starting work
  • Mount the contactor securely in the control compartment or electrical panel as directed by the equipment manufacturer
  • Move line, load, and control wires from the existing contactor to the new contactor, matching wiring diagrams and terminal markings
  • After energizing the system, verify that the contactor pulls in and opens cleanly, with proper operation during system start and stop cycles
  • Confirm that all terminations are tight and that wiring is supported to prevent strain at the terminals

Maintenance & Troubleshooting:

  • Inspect the contactor during routine HVAC maintenance for pitted or burned contacts, coil discoloration, or mechanical binding
  • Replace the contactor if the coil fails to energize, if the contacts do not close fully, or if there is evidence of overheating or excessive humming
  • If repeated contactor issues occur, verify that load current and control voltage are within specification and that short cycling is not overstressing the contactor

Certifications & Compliance:

  • Meets ARI 780/790 Standard

User Reviews & Q&A Summary:

  • Common theme is "correct part" for the intended replacement, with users reporting it worked as expected after installation
  • Review feedback frequently mentions straightforward installation for a direct replacement
  • Value and fulfillment are recurring positives (good deal/price and fast shipping)

Product Highlights

Product Highlight: Electrical Rating0.25 A @ 0.25 to 12 Vdc, 5.1A @ 240 Vac, 8A @ 120 Vac      Product Highlight: DifferentialFixed     Product Highlight: Switch ActionSPST, Contacts Break on Temp Rise     Product Highlight: MountHorizontal, Vertical     Product Highlight: Height5-5/8"     Product Highlight: Depth (Inches)2-1/8" Depth

Specs

Application:

High Limit

Low Limit

Bulb Size:

3/8" x 2-7/8"

Capillary Length:

3"

Switch Action:

SPST

Contacts Break on Temp Rise

Electrical Rating:

0.25 A @ 0.25 to 12 Vdc

5.1A @ 240 Vac

8A @ 120 Vac

Electrical Ratings (ALR):

48A @ 120 Vac

30.6A @ 240 Vac

Max Temp Differential:

2°F

Differential:

Fixed

Max Ambient Temp (°F):

150°F

Height:

5-5/8"

Width:

2"

Depth (Inches):

2-1/8"

Well Included:

No

Mount:

Horizontal

Vertical

Temperature Range (F):

40°F to 180°F