ICM203F Delay on Break Timer, 6″ Wire Leads (.03-10 Minute Knob Adjust. Delay)

SKU: ICM203F Brand:

$45.34each

12 People watching this product now!

Fast Shipping

Carrier information

20k products

Payment methods

24/7 Support

Unlimited help desk

2-day Delivery

Track or off orders

Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “ICM203F Delay on Break Timer, 6″ Wire Leads (.03-10 Minute Knob Adjust. Delay)”

Your email address will not be published. Required fields are marked *

Description

Delay on Break Timers ("anti-short cycle", "ON delay on break") helps to protect air conditioning, refrigeration and heat pump equipment from damage which may be caused by the rapid short cycling of compressors.

Features

  • Universal voltage operation
  • Higher 1.5 amp power rating
  • Compressor lockout-anti-short cycle timer
  • .03-10 minute (1.8-600 seconds) knob adjustable delay
  • Helps protect compressor from damage caused by rapid short cycling
  • Simple 2 wire hookup


Mode of Operation - Upon application power, the load is energized. When the thermostat or other switch opens or there is a loss of power, the load is de-energized and the delay period begins. The compressor will not start again during the delay period. Restart occurs after the delay period has elapsed.

Product Information

Standard Information

  • Brand: ICM Controls
  • MPN: ICM253
  • Category: HVAC Controls

Installation & Operation Notes:

  • Disconnect power at all sources and verify that all circuits are de-energized before starting work
  • Mount the contactor securely in the control compartment or electrical panel as directed by the equipment manufacturer
  • Move line, load, and control wires from the existing contactor to the new contactor, matching wiring diagrams and terminal markings
  • After energizing the system, verify that the contactor pulls in and opens cleanly, with proper operation during system start and stop cycles
  • Confirm that all terminations are tight and that wiring is supported to prevent strain at the terminals

Maintenance & Troubleshooting:

  • Inspect the contactor during routine HVAC maintenance for pitted or burned contacts, coil discoloration, or mechanical binding
  • Replace the contactor if the coil fails to energize, if the contacts do not close fully, or if there is evidence of overheating or excessive humming
  • If repeated contactor issues occur, verify that load current and control voltage are within specification and that short cycling is not overstressing the contactor

Certifications & Compliance:

  • Meets ARI 780/790 Standard

User Reviews & Q&A Summary:

  • Common theme is "correct part" for the intended replacement, with users reporting it worked as expected after installation
  • Review feedback frequently mentions straightforward installation for a direct replacement
  • Value and fulfillment are recurring positives (good deal/price and fast shipping)

Product Highlights

Product Highlight: Voltage18/240 VAC        Product Highlight: Amperage1.5 Amps       Product Highlight: Size2" x 2"
 

Specs

Time Delay:

.03-10 Min Knob Adjustable

Product Type:

Delay on Break

Wiring:

6" Wire Leads

2 Wire

Voltage:

18/240 VAC

Amperage:

1.5

Amp Inrush:

15

Frequency:

50-60 Hz

Voltage Drop:

3.5 V typical

4.5 V maximum @ 1.5amps

Holding Current:

40 mA (minimum)

Size:

2" x 2"

Â