Sealed Unit Parts S804520 Defrost Control Time Initiated Time Terminated

SKU: S804520 Brand:

$104.63each

13 People watching this product now!

Fast Shipping

Carrier information

20k products

Payment methods

24/7 Support

Unlimited help desk

2-day Delivery

Track or off orders

Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Sealed Unit Parts S804520 Defrost Control Time Initiated Time Terminated”

Your email address will not be published. Required fields are marked *

Description

The Sealed Unit Parts S804520 is a defrost control designed for reliable operation in refrigeration systems. This device features a time-initiated and time-terminated mechanism, providing flexibility in managing defrost cycles.

  • Heavy-duty synchronous motor for durable performance
  • Adjustable defrost initiation frequency from one to six times per day
  • Defrost cycle duration adjustable from four to 110 minutes in two-minute increments

Product Highlights

This defrost control is essential for optimizing refrigeration and preventing ice buildup, ensuring operational efficiency.

Product Information

Standard Information

  • UPC: 687152066131
  • UNSPSC: 46171603

Product Highlights

The Supco UET120 serves diverse industrial applications, including refrigeration and HVAC systems. Its long-lasting solid-state construction allows for reliable performance across multiple installations.

Product Information

Standard Information

  • Brand: Supco
  • MPN: UET120
  • Part Number: SUET120

Product Information

Standard Information

  • Brand: ICM Controls
  • MPN: ICM253
  • Category: HVAC Controls

Installation & Operation Notes:

  • Disconnect power at all sources and verify that all circuits are de-energized before starting work
  • Mount the contactor securely in the control compartment or electrical panel as directed by the equipment manufacturer
  • Move line, load, and control wires from the existing contactor to the new contactor, matching wiring diagrams and terminal markings
  • After energizing the system, verify that the contactor pulls in and opens cleanly, with proper operation during system start and stop cycles
  • Confirm that all terminations are tight and that wiring is supported to prevent strain at the terminals

Maintenance & Troubleshooting:

  • Inspect the contactor during routine HVAC maintenance for pitted or burned contacts, coil discoloration, or mechanical binding
  • Replace the contactor if the coil fails to energize, if the contacts do not close fully, or if there is evidence of overheating or excessive humming
  • If repeated contactor issues occur, verify that load current and control voltage are within specification and that short cycling is not overstressing the contactor

Certifications & Compliance:

  • Meets ARI 780/790 Standard

User Reviews & Q&A Summary:

  • Common theme is "correct part" for the intended replacement, with users reporting it worked as expected after installation
  • Review feedback frequently mentions straightforward installation for a direct replacement
  • Value and fulfillment are recurring positives (good deal/price and fast shipping)

Product Highlights

Product Highlight: Voltage18/240 VAC        Product Highlight: Amperage1.5 Amps       Product Highlight: Size2" x 2"
 

Specs

Time Delay:

.03-10 Min Knob Adjustable

Product Type:

Delay on Break

Wiring:

6" Wire Leads

2 Wire

Voltage:

18/240 VAC

Amperage:

1.5

Amp Inrush:

15

Frequency:

50-60 Hz

Voltage Drop:

3.5 V typical

4.5 V maximum @ 1.5amps

Holding Current:

40 mA (minimum)

Size:

2" x 2"

Â