Defrost Timer Multi Voltage, ICM550

SKU: ICM550 Brand:

$123.11each

13 People watching this product now!

Fast Shipping

Carrier information

20k products

Payment methods

24/7 Support

Unlimited help desk

2-day Delivery

Track or off orders

Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “Defrost Timer Multi Voltage, ICM550”

Your email address will not be published. Required fields are marked *

Description

Product Specifications for ICM550-LF:

  • Electrical Rating
    • Voltage: 120-240 VAC
    • Frequency: 60 Hz
  • Output
    • Type: Relay
    • Form: SPDT, SPST
  • Contact Ratings:
    • Compressor: [2]&[4]: 30A R, 1HP @ 120 VAC, 2HP @ 240 VAC
    • Electric heat: [1]&[3]: 40A R, 1HP @ 120 VAC, 2HP @ 240 VAC
    • Fan: [1]&[F]: 30A R, 1HP @ 120 VAC, 2HP @ 240 VAC
  • Timing:
    • Minimum cycle time: 15 min
    • Maximum cycle time: 23 hr 45 min
    • Terminate cycle: Cycle can be terminated by shorting "X to N"
  • Status LED:
    • Cycle mode: (Red LED)
    • Normal mode: (Green LED)

Product Highlights

The Supco UET120 serves diverse industrial applications, including refrigeration and HVAC systems. Its long-lasting solid-state construction allows for reliable performance across multiple installations.

Product Information

Standard Information

  • Brand: Supco
  • MPN: UET120
  • Part Number: SUET120

Product Information

Standard Information

  • Brand: ICM Controls
  • MPN: ICM253
  • Category: HVAC Controls

Installation & Operation Notes:

  • Disconnect power at all sources and verify that all circuits are de-energized before starting work
  • Mount the contactor securely in the control compartment or electrical panel as directed by the equipment manufacturer
  • Move line, load, and control wires from the existing contactor to the new contactor, matching wiring diagrams and terminal markings
  • After energizing the system, verify that the contactor pulls in and opens cleanly, with proper operation during system start and stop cycles
  • Confirm that all terminations are tight and that wiring is supported to prevent strain at the terminals

Maintenance & Troubleshooting:

  • Inspect the contactor during routine HVAC maintenance for pitted or burned contacts, coil discoloration, or mechanical binding
  • Replace the contactor if the coil fails to energize, if the contacts do not close fully, or if there is evidence of overheating or excessive humming
  • If repeated contactor issues occur, verify that load current and control voltage are within specification and that short cycling is not overstressing the contactor

Certifications & Compliance:

  • Meets ARI 780/790 Standard

User Reviews & Q&A Summary:

  • Common theme is "correct part" for the intended replacement, with users reporting it worked as expected after installation
  • Review feedback frequently mentions straightforward installation for a direct replacement
  • Value and fulfillment are recurring positives (good deal/price and fast shipping)

Product Highlights

Product Highlight: Voltage18/240 VAC        Product Highlight: Amperage1.5 Amps       Product Highlight: Size2" x 2"
 

Specs

Time Delay:

.03-10 Min Knob Adjustable

Product Type:

Delay on Break

Wiring:

6" Wire Leads

2 Wire

Voltage:

18/240 VAC

Amperage:

1.5

Amp Inrush:

15

Frequency:

50-60 Hz

Voltage Drop:

3.5 V typical

4.5 V maximum @ 1.5amps

Holding Current:

40 mA (minimum)

Size:

2" x 2"

Â