ICM102F Delay on Make Timer, 6″ Wire Leads (.03-10 Minute Adjustable Delay)

SKU: ICM102F Brand:

$37.09each

20 People watching this product now!

Fast Shipping

Carrier information

20k products

Payment methods

24/7 Support

Unlimited help desk

2-day Delivery

Track or off orders

Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “ICM102F Delay on Make Timer, 6″ Wire Leads (.03-10 Minute Adjustable Delay)”

Your email address will not be published. Required fields are marked *

Description

Mode of Operation - When power is applied to the input, the time delay begins. After the time delay is complete, the load energizes.

Delay on Make Timers are ideal for compressor staging and stagger starting multiple motors and other equipment. Helps to reduce power surges.

Features

  • Universal voltage operation
  • Higher 1.5 amp power rating
  • Knob-adjustable time delays
  • .03-10 minute (1.8-600 seconds) adjustable delay
  • Ideal for compressor staging
  • One model replaces many in field
  • Works with anticipator-type thermostats
  • Simple 2-wire hookup

Product Information

Standard Information

  • Brand: ICM Controls
  • MPN: ICM253
  • Category: HVAC Controls

Installation & Operation Notes:

  • Disconnect power at all sources and verify that all circuits are de-energized before starting work
  • Mount the contactor securely in the control compartment or electrical panel as directed by the equipment manufacturer
  • Move line, load, and control wires from the existing contactor to the new contactor, matching wiring diagrams and terminal markings
  • After energizing the system, verify that the contactor pulls in and opens cleanly, with proper operation during system start and stop cycles
  • Confirm that all terminations are tight and that wiring is supported to prevent strain at the terminals

Maintenance & Troubleshooting:

  • Inspect the contactor during routine HVAC maintenance for pitted or burned contacts, coil discoloration, or mechanical binding
  • Replace the contactor if the coil fails to energize, if the contacts do not close fully, or if there is evidence of overheating or excessive humming
  • If repeated contactor issues occur, verify that load current and control voltage are within specification and that short cycling is not overstressing the contactor

Certifications & Compliance:

  • Meets ARI 780/790 Standard

User Reviews & Q&A Summary:

  • Common theme is "correct part" for the intended replacement, with users reporting it worked as expected after installation
  • Review feedback frequently mentions straightforward installation for a direct replacement
  • Value and fulfillment are recurring positives (good deal/price and fast shipping)

Product Highlights

Product Highlight: Voltage18/240 VAC       Product Highlight: Amperage1.5 Amps       Product Highlight: Size2" x 2"

Specs

Time Delay:

.03-10 Min Adjustable

Product Type:

Delay on Make

Wiring:

6" Wire Leads

2-Wire

Voltage:

18/240 VAC

Amperage:

1.5

Amp Inrush:

15

Holding Current:

40 mA

Size:

2" x 2"

Voltage Drop:

2.5v @1amp