Gas Ignition Control Board - replacement for Rheem 62-24140-04 control boards.

Specifications:

  • Control Voltage: 24 VAC (18-30 VAC), 60Hz
  • Line Voltage: 115 VAC, 60Hz


Timing:

  • Pre-Purge: 30 seconds
  • Trial for Ignition: 7 seconds
  • Retries: Two groups of two, 30 second delay within the group, and 3 minute delay between groups
  • Lockout: 1-hour
  • Post-Purge: 90, 120, 160 and 180 seconds


Inputs:

  • Power: 24 VAC and COM
  • Thermostat Interface: R,W, Y, and G
  • System Switches: Vent pressure and limit switches (main and over-temperature switches in series)
  • Flame Sensing
  • Heat Blower OFF Delay (miniature slide switch set)


Outputs:

  • Spark
  • Gas Valve: GV
  • Inducer Draft Motor: IDM
  • Blower Motor: FAN, COOL and HEAT speeds
  • Electric air Cleaner: EAC
  • Humidifier Relay: HUM
  • Heat/Cool Relay: H/C


LED Indicators:

  • Power, Green LED: PWR
  • Status, Green LED: OK
  • Flame Status, Yellow LED: FLAME


Patents:

  • #6,222,719: Ignition Boost
  • #5,917,691: Fail Safe Relay Driver

Product Features

  • Universal Furnace Electronic Fan Timer control for single stage furnaces with PSC inducer and blower motors
  • Works with non-integrated furnace controls or intelligent gas valves
  • Six mounting hole options
  • Harnesses with terminal flags for easy wiring
  • Terminals are labeled to match multiple existing boards
  • Transformer connections offer 1/4" and 3/16" terminals
  • Tri-Color LED displays status and fault codes
  • Exclusive fault recall button

Product Specifications

  • Stages: Single Stage
  • Operating Voltage: Input 24 Vac, 60 Hz
  • Line Voltage: 115-230 Vac, 60 Hz
  • Inducer Motor/Blower Motor: PSC
  • Ambient Operating Temperature: -40 to 175°F (-40 to 80°FC)
  • Humidity Range: 5% to 95% relative humidity (non-condensing)

Product Specifications:

  • Description: 1/2 in. NPT x 1/2 in. NPT Intermittent Hot Surface Pilot Ignition SmartValve Control with fast-fast opening and 3.4 in. wc pressure regulator setting
  • Flame Sense: Electrode
  • Type of Gas: Natural
  • Ignition System Type: Intermittent Hot Surface Pilot Ignition
  • Ignition Sequence: Intermittent Pilot
  • Ignition Source: Pilot
  • Ignition Trials To Lockout: Continuous Retry
  • PrePurge: None
  • Body Pattern: Straight-through
  • Opening Characteristics: Fast-Fast Opening
  • Ignition Trial Time (sec): 90 sec
  • Electrical Ratings: 24 Vac
  • Frequency: 60 Hz; 50 Hz
  • Flame Failure Response Time (sec): 1.6 sec @ 3 µA
  • Ambient Temperature Range (F): -40 F to +175 F
  • Ambient Temperature Range (C): -40 C to +79 C
  • Pressure Regulator Setting (psi): 3.4 in. wc
  • Pressure Regulator Setting (kPa): 0.87 kPa
  • Pressure Ratings (psi): 1/2 psi
  • Pressure Ratings (kPa): 3.45 kPa
  • Inlet/Outlet Size (in.): 1/2 in. NPT x 1/2 in. NPT
  • Maximum Capacity (ft³/hr): 200 ft³/hr
  • Maximum Capacity (m³/hr): 5.7 m³/hr
  • Minimum Capacity (ft³/hr): 20 ft³/hr
  • Minimum Capacity (m³/hr): 0.6 m³/hr
  • Maximum Capacity at 1 in. P.D. (ft³/hr): 150 ft³/hr
  • Maximum Capacity at 1 in. P.D. (m³/hr): 4.2 m³/hr
  • Pilot Gas Outlet: Yes
  • Typical Ignition Hardware: Q3450
  • Approvals, American Gas Association IAS: IAS Design Certified: C2030017

Maintenance & Troubleshooting:

  • This capacitor is typically replaced when diagnostics indicate a run capacitor is out of specification or when motor operation issues are traced to the dual run capacitor (diagnostic procedures are not provided in the supplied sources).
  • If issues persist after replacement, confirm the installed capacitor matches the required MFD and voltage ratings and that all connections are correct per the equipment documentation.

Certifications & Compliance:

  • Manufacturer listing states UL & cUL for these capacitors.

User Reviews & Q&A Summary:

  • Review themes commonly describe it as a correct replacement capacitor that restores cooling operation when a failed capacitor is replaced.
  • Many comments focus on getting the right part quickly and returning equipment to service, with frequent notes about straightforward replacement once the correct rating is confirmed.

Product Highlights

Product Highlight: Voltage  Line (98/132 VAC) @ 60 Hz

Specs

Product Type:

Control Board

Control Voltage:

24 VAC @ 60 Hz

Line Voltage:

115 VAC, 60Hz

Power Consumption:

0.3A plus gas valve current at 24 VAC

Operating Temp Range:

-40° to 176°F

Pre-Purge Time:

30 Seconds

Trial For Ignition:

7 Seconds

Thermostat Terminals:

R, W, Y and G