ICM517 Single Phase Surge Protective Device w/ Metal, NEMA Type 3R Enclosure

SKU: ICM517

$101.33each

18 People watching this product now!

Fast Shipping

Carrier information

20k products

Payment methods

24/7 Support

Unlimited help desk

2-day Delivery

Track or off orders

Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “ICM517 Single Phase Surge Protective Device w/ Metal, NEMA Type 3R Enclosure”

Your email address will not be published. Required fields are marked *

Description

Suitable for use on a circuit capable of delivering not more than 10,000 rms symmetrical amps, 240 volts max, when protected by a circuit breaker rated 20 to 60 amps maximum and 120 volts minimum.

Features:

  • Single Phase Surge Protective Device
  • UL Listed, Type 2 Device
  • Metal, NEMA Type 3R Rated Enclosure
  • Rugged, Reliable
  • Easy Indoor/Outdoor Installation
  • LED Status Indicators
  • Backed by a Limited Lifetime Protection Warranty


Surge Protection For:

  • Refrigeration Systems
  • Motors
  • Air Conditioners
  • Appliances
  • Electronics

Product Features

  • Universal Furnace Electronic Fan Timer control for single stage furnaces with PSC inducer and blower motors
  • Works with non-integrated furnace controls or intelligent gas valves
  • Six mounting hole options
  • Harnesses with terminal flags for easy wiring
  • Terminals are labeled to match multiple existing boards
  • Transformer connections offer 1/4" and 3/16" terminals
  • Tri-Color LED displays status and fault codes
  • Exclusive fault recall button

Product Specifications

  • Stages: Single Stage
  • Operating Voltage: Input 24 Vac, 60 Hz
  • Line Voltage: 115-230 Vac, 60 Hz
  • Inducer Motor/Blower Motor: PSC
  • Ambient Operating Temperature: -40 to 175°F (-40 to 80°FC)
  • Humidity Range: 5% to 95% relative humidity (non-condensing)

Product Specifications:

  • Description: 1/2 in. NPT x 1/2 in. NPT Intermittent Hot Surface Pilot Ignition SmartValve Control with fast-fast opening and 3.4 in. wc pressure regulator setting
  • Flame Sense: Electrode
  • Type of Gas: Natural
  • Ignition System Type: Intermittent Hot Surface Pilot Ignition
  • Ignition Sequence: Intermittent Pilot
  • Ignition Source: Pilot
  • Ignition Trials To Lockout: Continuous Retry
  • PrePurge: None
  • Body Pattern: Straight-through
  • Opening Characteristics: Fast-Fast Opening
  • Ignition Trial Time (sec): 90 sec
  • Electrical Ratings: 24 Vac
  • Frequency: 60 Hz; 50 Hz
  • Flame Failure Response Time (sec): 1.6 sec @ 3 µA
  • Ambient Temperature Range (F): -40 F to +175 F
  • Ambient Temperature Range (C): -40 C to +79 C
  • Pressure Regulator Setting (psi): 3.4 in. wc
  • Pressure Regulator Setting (kPa): 0.87 kPa
  • Pressure Ratings (psi): 1/2 psi
  • Pressure Ratings (kPa): 3.45 kPa
  • Inlet/Outlet Size (in.): 1/2 in. NPT x 1/2 in. NPT
  • Maximum Capacity (ft³/hr): 200 ft³/hr
  • Maximum Capacity (m³/hr): 5.7 m³/hr
  • Minimum Capacity (ft³/hr): 20 ft³/hr
  • Minimum Capacity (m³/hr): 0.6 m³/hr
  • Maximum Capacity at 1 in. P.D. (ft³/hr): 150 ft³/hr
  • Maximum Capacity at 1 in. P.D. (m³/hr): 4.2 m³/hr
  • Pilot Gas Outlet: Yes
  • Typical Ignition Hardware: Q3450
  • Approvals, American Gas Association IAS: IAS Design Certified: C2030017

Maintenance & Troubleshooting:

  • This capacitor is typically replaced when diagnostics indicate a run capacitor is out of specification or when motor operation issues are traced to the dual run capacitor (diagnostic procedures are not provided in the supplied sources).
  • If issues persist after replacement, confirm the installed capacitor matches the required MFD and voltage ratings and that all connections are correct per the equipment documentation.

Certifications & Compliance:

  • Manufacturer listing states UL & cUL for these capacitors.

User Reviews & Q&A Summary:

  • Review themes commonly describe it as a correct replacement capacitor that restores cooling operation when a failed capacitor is replaced.
  • Many comments focus on getting the right part quickly and returning equipment to service, with frequent notes about straightforward replacement once the correct rating is confirmed.

Product Highlights

Product Highlight: Voltage 120/240V

Specs

Voltage:

120/240V

Max Surge Current:

100000 amps

Max Energy Dissipation:

1020 Joules

Installation Point:

Electrical Panel

Electrical Disconnect

AC Protection Modes:

Line-line

Line-ground

Line-neutral

Neutral-ground

Â