503 Series Foot Mount Transformer 120/208/240 to 24V 40VA

SKU: 50354-MARS

$24.77each

10 People watching this product now!

Fast Shipping

Carrier information

20k products

Payment methods

24/7 Support

Unlimited help desk

2-day Delivery

Track or off orders

Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “503 Series Foot Mount Transformer 120/208/240 to 24V 40VA”

Your email address will not be published. Required fields are marked *

Description

MARS compact open construction transformers are less than 2-1/4" in height. This makes them ideal as replacements within existing equipment. MARS control transformers are available with various outputs and voltages for special applications.

Features:

  • UL class 2 recognized
  • Low heat rise
  • Primary color coded leads
  • Secondary color coded leads, or 1/4" male quick connects
  • Foot-mount
 

Compatibility & Applications:

  • Intended for use in air conditioners, heat pumps, and other HVAC equipment requiring a 2-pole, 40 amp, 24V coil contactor
  • Suitable for residential and light commercial outdoor units, air handlers, and other equipment within the contactor's ratings
  • Used as a replacement where equipment specifications call for a 2-pole contactor with similar electrical ratings and coil voltage

Installation & Operation Notes:

  • Disconnect power at all sources and verify that all circuits are de-energized before starting work
  • Mount the contactor securely in the control compartment or electrical panel as directed by the equipment manufacturer
  • Move line, load, and control wires from the existing contactor to the new contactor, matching wiring diagrams and terminal markings
  • After energizing the system, verify that the contactor pulls in and opens cleanly, with proper operation during system start and stop cycles
  • Confirm that all terminations are tight and that wiring is supported to prevent strain at the terminals

Maintenance & Troubleshooting:

  • Inspect the contactor during routine HVAC maintenance for pitted or burned contacts, coil discoloration, or mechanical binding
  • Replace the contactor if the coil fails to energize, if the contacts do not close fully, or if there is evidence of overheating or excessive humming
  • If repeated contactor issues occur, verify that load current and control voltage are within specification and that short cycling is not overstressing the contactor

Certifications & Compliance:

  • Meets ARI 780/790 Standard

User Reviews & Q&A Summary:

  • Common theme is "correct part" for the intended replacement, with users reporting it worked as expected after installation
  • Review feedback frequently mentions straightforward installation for a direct replacement
  • Value and fulfillment are recurring positives (good deal/price and fast shipping)

Product Highlights

Product Highlight: MountFoot

Specs

Product Type:

Transformer

Voltage (Primary):

240V

208V

120V

Voltage (Secondary):

24v

VA Rating:

40

Mount:

Foot

Â