ICM206 Delay on Break Timer (3-10 Minute Adjustable Delay)

SKU: ICM206B

$54.71each

10 People watching this product now!

Fast Shipping

Carrier information

20k products

Payment methods

24/7 Support

Unlimited help desk

2-day Delivery

Track or off orders

Reviews (0)
0 reviews
0
0
0
0
0

There are no reviews yet.

Be the first to review “ICM206 Delay on Break Timer (3-10 Minute Adjustable Delay)”

Your email address will not be published. Required fields are marked *

Description

Delay on Break Timers ("anti-short cycle", "ON delay on break") helps to protect air conditioning, refrigeration and heat pump equipment from damage which may be caused by the rapid short cycling of compressors.

Features

  • Brownout protection
  • UL 873 recognition as compressor controller
  • Helps prevent scroll compressor reversal
  • 3-10 minute adjustable time delay
  • Fast response time: 16ms
  • Prevents low voltage starts
  • Eliminates relay chatter due to thermostat bounce or tampering
  • Works with anticipator-type thermostats Patented: US Parent No. 4,991,049

Mode of Operation - Upon application power, the load is energized. When the thermostat or other switch opens or there is a loss of power, the load is de-energized and the delay period begins. The compressor will not start again during the delay period. Restart occurs after the delay period has elapsed.

Installation & Operation Notes:

  • Disconnect power at all sources and verify that all circuits are de-energized before starting work
  • Mount the contactor securely in the control compartment or electrical panel as directed by the equipment manufacturer
  • Move line, load, and control wires from the existing contactor to the new contactor, matching wiring diagrams and terminal markings
  • After energizing the system, verify that the contactor pulls in and opens cleanly, with proper operation during system start and stop cycles
  • Confirm that all terminations are tight and that wiring is supported to prevent strain at the terminals

Maintenance & Troubleshooting:

  • Inspect the contactor during routine HVAC maintenance for pitted or burned contacts, coil discoloration, or mechanical binding
  • Replace the contactor if the coil fails to energize, if the contacts do not close fully, or if there is evidence of overheating or excessive humming
  • If repeated contactor issues occur, verify that load current and control voltage are within specification and that short cycling is not overstressing the contactor

Certifications & Compliance:

  • Meets ARI 780/790 Standard

User Reviews & Q&A Summary:

  • Common theme is "correct part" for the intended replacement, with users reporting it worked as expected after installation
  • Review feedback frequently mentions straightforward installation for a direct replacement
  • Value and fulfillment are recurring positives (good deal/price and fast shipping)

Product Highlights

Product Highlight: Voltage18/30 VAC      Product Highlight: Amperage1.5 Amps     Product Highlight: Size2" x 2"

Specs

Product Type:

Delay on Break

Time Delay:

3-10 Min Adjustable

Voltage:

18/30 VAC

Amperage:

1.5

Amp Inrush:

15

Frequency:

50-60 Hz

Holding Current:

40 mA (minimum)

Size:

2" x 2"

Replaces:

TD74

EAC-426-ADJ

OEM:

A-1

Supco