Packard C240A 2-Pole Contactor, 24V, 40 Amp, is a definite purpose contactor used in HVAC and light commercial systems to switch two-pole loads such as condenser or heat pump compressors and fan motors with a 24 volt coil signal.

Key Features:

  • OEM Packard 2-pole definite purpose contactor
  • 40 amp resistive load rating for typical HVAC condenser and heat pump applications
  • 24 VAC coil for control by standard low voltage thermostat or control circuits
  • Two poles of power switching for disconnecting both sides of the load when de-energized
  • Compact open-frame design for installation in equipment control compartments
  • Line, load, and coil terminals arranged for straightforward field wiring

Compatibility & Applications:

  • Intended for use in air conditioners, heat pumps, and other HVAC equipment requiring a 2-pole, 40 amp, 24V coil contactor
  • Suitable for residential and light commercial outdoor units, air handlers, and other equipment within the contactor's ratings
  • Used as a replacement where equipment specifications call for a 2-pole contactor with similar electrical ratings and coil voltage

Installation & Operation Notes:

  • Disconnect power at all sources and verify that all circuits are de-energized before starting work
  • Mount the contactor securely in the control compartment or electrical panel as directed by the equipment manufacturer
  • Move line, load, and control wires from the existing contactor to the new contactor, matching wiring diagrams and terminal markings
  • After energizing the system, verify that the contactor pulls in and opens cleanly, with proper operation during system start and stop cycles
  • Confirm that all terminations are tight and that wiring is supported to prevent strain at the terminals

Maintenance & Troubleshooting:

  • Inspect the contactor during routine HVAC maintenance for pitted or burned contacts, coil discoloration, or mechanical binding
  • Replace the contactor if the coil fails to energize, if the contacts do not close fully, or if there is evidence of overheating or excessive humming
  • If repeated contactor issues occur, verify that load current and control voltage are within specification and that short cycling is not overstressing the contactor

Certifications & Compliance:

  • Meets ARI 780/790 Standard

User Reviews & Q&A Summary:

  • Common theme is "correct part" for the intended replacement, with users reporting it worked as expected after installation
  • Review feedback frequently mentions straightforward installation for a direct replacement
  • Value and fulfillment are recurring positives (good deal/price and fast shipping)

Product Highlights

Product Highlight: Voltage24V      Product Highlight: Amperage40 Amps

Specs

Voltage:

24V

Amperage:

40

Poles:

2